Register to Win the Flying Cross & Vertx Giveaway Package

Draeger Tube, Mercaptan 0.5/a 0.5-5 ppm, Box of 10

Draeger Tube, Mercaptan 0.5/a 0.5-5 ppm, Box of 10

$123.00
Availability: May direct ship from manufacturer.
Product Code: 6728981

Draeger Tube - Mercaptan 0.5/a
Order No. 67 28 981

Application Range
Standard Measuring Range 0.5 to 5 ppm
Number of Strokes n: 20
Time for Measurement: approx. 5 minutes
Standard Deviation: ± 10 to 15%
Color Change: white to yellow
Ambient Operating Conditions
Temperature: 10 to 40° C ~ 50 to 104° F
Absolute Humidity: 3 to 15 mg H2O / L
Reaction Principle
2 R-SH + Pd2+  Pd(RS)2 + 2 H+
Cross Sensitivity
Higher molecular weight alkyl mercaptans (e.g. propyl- and butylmercaptans) are indicated with approximately the same sensitivity. 1,000 ppm ethylene, 2,000 ppm carbon monoxide and 200 ppm hydrogen sulfide do not affect the indication. Hydrogen sulfide discolors the pre-layer black.