Draeger Tube, Phosgene 0.02/a 0.02-1 ppm

$100.00
Availability: Call for Availability
Product Code: 8101521
Brand: DRAEGER SAFETY INC.
+

 

Draeger Tube - Phosgene 0.02/a
Order No. 81 01 521

Application Range
Standard Measuring Range 0.02 to 1 ppm / 0.02 to 0.6 ppm
Number of Strokes n: 20 / 40
Time for Measurement: approx. 6 minutes / approx. 12 minutes
Standard Deviation: ± 10 to 15%
Color Change: white to red
   
Ambient Operating Conditions
Temperature: 0 to 40° C ~ 32 to 104° F
Absolute Humidity: 3 to 15 mg H2O / L
   
Reaction Principle
COCI2 + aromatic amine → red reaction product
 
Cross Sensitivity
Chlorine and hydrochloric acid lead to plus errors and, at higher concentrations, to bleaching of the indicating layer. Concentrations of phosgene above 30 ppm will also lead to bleaching of the indicating layer.
 
Additional Information
High concentrations of phosgene will be not indicated!